Return belt misalignment is detected by two downcast arms, which are connected to an electrical switch by a glass reinforced polycarbate coupling.
.
If the belt misaligns on either side to the extent that it could cause damage to the belt or conveyor structure, it contacts one of the downcast arms. The arm tilts in the direction of the moving belt and activates the switch.
.
•Adjustable mechanical trip delay on the switch coupling mechanism prevents false trips.
•Switch structure is designed to minimize material build-up which could render the switch inoperable.
•Belt protection units can be combined to meet your specific needs.
.
Specifications:
•Part Number: CTS 700 RBL
•Enclosure: I.P. 66
•Housing: High Impact Polycarbonate
•Switch: Rated 16A/500V
(2 normally open and 2 normally closed contacts)
.